Thermal Mass in Passive Solar Design

People have been talking about passive solar buildings for a long time, although there have been surprisingly few actually built during that time. In the 1970’s and early 1980’s (around the time of the first energy crisis), passive solar design began to emerge and many architects and builders experimented with it, with varying degrees of success.

The basic principles are pretty straight forward, but getting all the details right can be challenging. Probably the biggest issue is finding the right combination of windows to let the sun’s energy in, and amount of thermal mass to store that energy. Thermal mass in passive solar homes can be concrete or tile floors, concrete walls, and large tanks of water. The important element in thermal mass is that heat from the sun needs to be able to hit the mass, either directly or indirectly, to heat it up.

If it is covered with carpet, wood, or in the case of insulated concrete forms (ICFs), insulation, then it won’t be able to absorb enough heat to work.Thermal mass serves two purposes – capturing and releasing heat energy from the sun. It soaks up heat during the day, helping to keep a home from overheating, then, when the sun and the temperature start to go down, it releases the heat into the house, keeping it warm overnight, and often during cloudy days.

The big question in passive solar design is exactly how much thermal mass to install. The amount of thermal mass is determined by the total area of south facing windows. If there is too little mass, not enough heat will be absorbed, allowing the house to overheat during the day and not releasing enough stored heat at night. There is less of a risk putting in too much thermal mass, but it is pretty expensive stuff, so you want to avoid overdoing it, unless you like to waste a lot of money on things you can’t see.

Some rules of thumb to consider: If your south facing window area is less than 7% of the floor area of the house, you won’t need any extra thermal mass (but you won’t be getting much passive solar heating when the sun goes down). For every square foot (SF) of south facing glass over that 7%, you need about 5½ SF of 4” thick floor mass, like a concrete slab. If you are going to use your walls for the mass, then you need to have about 8 SF of 4” thick material. Remember that the mass needs to be exposed and not covered with carpet or similar finishes to work properly. The mass to window ratios can vary based on the climate and building features.

One key to good passive solar design is to plan a house that has windows and thermal mass in all the major rooms. If you don’t, then you have to figure out a way to circulate the heat into rooms that aren’t heated by the sun. Also, keep in mind that most people want cooling and dehumidification in their homes during warm weather,so even with passive solar heating, you may still need some air conditioning to keep the house comfortable in a hot climate like Atlanta.

On one level, passive solar design is a bit of a misnomer. It is passive in the sense that it doesn’t use fluids and pumps, ducts and blowers, and other mechanical equipment to heat the house. It is, however anything but passive for the homeowners. They need to be very active about opening and closing blinds to let heat in during the day and keep it from flowing out through the windows at night. Interior doors need to be opened and closed to let heat flow through the entire house. Some HVAC systems in passive solar houses even include ducts and fans to circulate heat throughout the entire house. They also need to open windows when the weather is temperate to take advantage of natural heating and cooling when available.

Passive solar design is not for everyone, but for those people who understand it and are willing to live actively in one of these homes, they can be very comfortable and extremely efficient.

Tags: ,

HVAC Industry News

Can I Still Install a 13 SEER Unit?

There are three key questions to ask when considering installing a 13 SEER unit. Which region you are in? When was the 13 SEER system built? Was it a heat pump or straight AC? You can still install a 13 SEER unit anywhere in the U.S. if it was manufactured before Jan. 1, 2015. If … Read More »

Emerson Climate Technologies Announces The Release Of CopelandTM Brand Products For R404A/ R507A And R134a Refrigerant Alternatives

AACHEN (GERMANY), October 15, 2014 — Emerson Climate Technologies, a business of Emerson (NYSE: EMR), announces its ongoing investment in sustainable refrigerant alternatives in anticipation of European Union rules. Both the European Union and U.S. EPA have announced plans to transition new applications away from high global warming potential refrigerants (R404A/ R507A). F-gas Regulation 517/2014 … Read More »

New Air Conditioner Standards Would Rank as Biggest Energy Saver in U.S. DOE History

Proposed Standards Would Save Businesses Billions Washington, D.C.—The Department of Energy (DOE) proposed new efficiency standards today that would slash commercial rooftop air conditioner energy use by about 30%. The proposed standards would achieve the largest national energy savings of any standard ever issued by the U.S. Department of Energy. “DOE’s new standards are a … Read More »

EPA Warns Against Use of Refrigerant Substitutes That Pose Fire and Explosion Risk

WASHINGTON – The U.S. Environmental Protection Agency (EPA) is warning homeowners, propane manufacturers and sellers, home improvement contractors and air conditioning technicians of potential safety hazards related to the use of propane or other unapproved refrigerants in home air conditioning systems. EPA is currently investigating instances where propane has been marketed and used as a … Read More »

%d bloggers like this: