COMMERCIAL COOLING SYSTEM
Urgent Air’s Cooling Systems Multi-Point inspections include the following:
Air Conditioning (Straight Cool):
Inspect voltage
Inspect amp draw
Inspect proper fuse sizing
Inspect all electrical connections
Inspect safety controls and operations
Inspect the thermostat and operation
Inspect filter conditions
Address any customer concerns
Inspecting blower motor amps
Inspect blower motor temperature
Inspect blower motor bearings
Inspect blower motor capacitor
Inspect blower wheel condition
Inspect the supply duct
Inspect the return duct
Inspect supply air temperature
Inspect return air temperature
Inspect air flow
Inspect system noise and operation
Adjust vents if requested
Inspect the condensate drain and vent
Clear the condensate drain of any debris
Inspect drain overflow
Inspect dryers
Inspect metering devices
Confirm pressures, if an issue is suspected
Inspect service valves
Inspect condition of the evaporator coil
Inspect condition of the condenser coil
Wash condenser coil with water if available
Inspect contactor
Inspect condenser fan motor amps
Inspect condenser fan motor capacitor
Inspect condenser fan motor bearings
Inspect condenser fan motor temperature
Inspect condenser fan blade condition
Inspect compressor amp draw
Inspect compressor run/start components
Inspect suction temperature of compressor
Inspect discharge temperature of compressor
Inspect and adjust belts
Inspect the economizer
Inspect smoke detection
Air Conditioning (Heat Pump):
Inspect voltage
Inspect amp draw
Inspect proper fuse sizing
Inspect all electrical connections
Inspect safety controls and operations
Inspect the thermostat and operation
Inspect filter conditions
Address any customer concerns
Inspecting blower motor amps
Inspect blower motor temperature
Inspect blower motor bearings
Inspect blower motor capacitor
Inspect blower wheel condition
Inspect the supply duct
Inspect the return duct
Inspect supply air temperature
Inspect return air temperature
Inspect air flow
Inspect system noise and operation
Adjust vents if requested
Inspect the condensate drain and vent
Clear the condensate drain of any debris
Inspect drain overflow
Inspect dryers
Inspect metering devices
Confirm pressures, if issue is suspected
Inspect service valves
Inspect condition of the evaporator coil
Inspect condition of the condenser coil
Wash condenser coil with water if available
Inspect contactor
Inspect condenser fan motor amps
Inspect condenser fan motor capacitor
Inspect condenser fan motor bearings
Inspect condenser fan motor temperature
Inspect condenser fan blade condition
Inspect compressor amp draw
Inspect compressor run/start components
Inspect suction temperature of compressor
Inspect discharge temperature of compressor
Inspect operation of reversing valve
Inspect and adjust belts
Inspect the economizer
Inspect smoke detection